Details of experiments between Q15599 and Q82005
Note that the results of all experiments are listed, regardless of the modification states of the fragments.



Experiment series 1

Protein A protein: NHERF2
Protein A fragment: 9-91
Protein A site: PDZ_1
Protein A construct: his6-MBP-TEVsite-PDZ

Protein B protein: HPV73-E6
Protein B fragment: 139-148
Protein B site: PBM
Protein B sequence: SGSRPSATVV
Protein B construct: biotin-ttds-SGSRPSATVV

Average holdup BI: 0.02
Immobilized partner concentration in holdup experiment (10-6M): 10
Experiment method: SAPF_holdup
Details of affinity fitting: fluorescein + mCherry internal standards + normal layout
PUBMED ID of publication: 36115835
Number of measurements: 1
The affinity was below the detection threshold of the assay.


Experiment series 2

Protein A protein: NHERF2
Protein A fragment: 142-238
Protein A site: PDZ_2
Protein A construct: his6-MBP-TEVsite-PDZ

Protein B protein: HPV73-E6
Protein B fragment: 139-148
Protein B site: PBM
Protein B sequence: SGSRPSATVV
Protein B construct: biotin-ttds-SGSRPSATVV

Average holdup BI: 0.02
Immobilized partner concentration in holdup experiment (10-6M): 10
Experiment method: SAPF_holdup
Details of affinity fitting: fluorescein + mCherry internal standards + normal layout
PUBMED ID of publication: 36115835
Number of measurements: 1
The affinity was below the detection threshold of the assay.


Experiment series 3

Protein A protein: NHERF2
Protein A fragment: 142-238
Protein A site: PDZ_2
Protein A construct: his6-MBP-TEVsite-PDZ

Protein B protein: HPV73-E6
Protein B fragment: 139-148
Protein B site: PBM
Protein B sequence: SGSRPSATVV
Protein B construct: biotin-ttds-SGSRPSATVV

Average holdup BI: 0.03
Normalized holdup BI: 0.03
Immobilized partner concentration in holdup experiment (10-6M): 18
Experiment method: DAPF_holdup
Details of affinity fitting: fluorescein + mCherry internal standards + normalization based on CALIP_holdup data + reverse layout
PUBMED ID of publication: 36115835
Number of measurements: 1